Quick Details

  • Place of Origin: Guangdong, China (Mainland)
  • Brand Name: ETCR
  • Model Number: ETCR3200
  • Display Type: Digital Only
  • Measuring Range: AC0.00mA~600A
  • Testing Voltage: 0~100V
  • Accuracy Class: 0.00mA
  • Operating Temperature: -10~40 Degree
  • Dimensions: 215*190*95mm

Packaging & Delivery

Packaging Details 1. 455*315*140 mm 1pcs/carton G.W.: 8KG;
2. 512*480*185 mm 3pcs/carton G.W:24KG
Delivery Time 5~15days

New Product!  ETCR3200 Double Clamp Grounding Resistance Tester


l  The measurement of earth resistance, soil resistivity, earth voltage, leakage current of grounding line, AC current, DC resistance

l  Test mode: precise 4-pole, 3-pole and simple 2-pole method, selection method, double clamp method

l  With strong anti-interfere ability, high stability and reliability for prolonged measure, and high accuracy

l  Size of clamp: Φ68mm

l  Testing frequency:128Hz/111Hz/105Hz/94Hz(AFC)

l  Range of grounding resistance:0.00Ω~30kΩ

l  Range of soil resistivity:0.00Ωm~9000kΩm

l  Range of grounding voltage:0~100V

l  Range of current:AC0.00mA~600A

l  Data upload by RS232 interface, alarm function

l  Storage of data:2000sets



Technology specification





measure grounding resistance, soil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current 

Power Supply 

DC 9V(Zn-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours ) 

Caliber of clamp 


Accuracy of range
( error base on basic condition) 

Test function 




2/3/4 pole method measure grounding resistance(R) 

0.00Ω ~ 30.00Ω 



30.0Ω ~ 300.0Ω 



300Ω ~ 3000Ω



3.00kΩ ~ 30kΩ



Selection method measure grounding resistance(R) 

0.00Ω ~ 30.00Ω 



30.0Ω ~ 300.0Ω 



300Ω ~ 3000Ω



Double clamp method measure grounding resistance(R) 

0.01Ω ~ 1.00Ω



1.0Ω ~ 10.0Ω 



10Ω ~ 100Ω 



Soil Resistivity ( ρ ) 

0.00Ωm ~ 99.99Ωm 

Base on the measurement accuracy of R 
( ρ=2πaR a :1 m ~ 100m ; π =3.14) 


100.0Ωm ~ 999.9Ωm 


1000Ωm ~ 9999Ωm 


10.00kΩm ~ 99.99kΩm 


100.0kΩm ~ 999.9kΩm 


1000kΩm ~ 9000kΩm 


Earth voltage 

AC 0.0 ~ 100.0V 



AC current 

0.00mA ~ 600.0A 



Measuring Method 

2/3/4 pole method: change-pole method, measurement current 20mA Max 

Selection method: change-pole method, measurement current 20mA Max 

Double clamp method: disconnect mutual inductance method, measurement current 1mA Max 

Soil Resistivity: 4-pole measurement (Wenner method) 

Earth Voltage: average rectification(between P (S) - ES ) 

AC current: mutual inductance method 

Test Frequency 

128Hz/111Hz/105Hz/94Hz( AFC ) 

Short-circuit Current 

AC 20mA max 

Open-circuit Current 

AC 40V max 

Display Mode 

4-digital super-large LCD display, blue screen backlight 

LCD Dimension 

128mm ×75mm ; LCD demon: 124mm×67mm 


LxWxH: 215mm ×190mm×95mm 

Testing line 

6wires:red 20m ,black 20m ,yellow 10m ,green 10m ,red 1.6m ,black 1.6m one piece for each 

Auxiliary Earthing Rod 

4 pc: φ10mm×150mm 

RS232 interface 

RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed; RS232 line:1 piece, 1.5m long; 

Data Storage 

2000 sets, “ MEM ” icon storage indicator, flash display “ FULL ” icon to indicate storage is full 

Interference Test 

Recognize interference signal automatically, “ NOISE ” means interference voltage exceed 5V 

Auxiliary Earthing Test 

Can measure auxiliary earth resistance, 0.00KΩ - 30kΩ(100 R + rC <50kΩ , 100 R + rP <50kΩ) 

Alarm Function 

When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint 

Battery Voltage 

When battery voltage is below7.5V, icon    will display, reminding to replace battery. 

Auto-shut off 

Automaticlly shut down 15minutes after booting 

Power Consumption 

Standby: about 20mA (Backlight shut off); Boot and with backlight: about 45mA (25mA without backlight); Measurement: about 100mA (Backlight shut off) 


Total weight: 8kg ;meter: 1653g( with battery ) ;clamp: 1050g (2 pc ) ; testing line: 1560g ; Auxiliary earthing rods: 935g (4pcs) 


-10 °C ~ 40 °C ;below 80%rh 

Overload Protection 

Measuring earth resistance: between each interfaces of C (H) -E , P (S) -ES , AC 280V/3 seconds 

Insulation Resistance 

Over 20MΩ (between circuit and enclosure it is 500V) Withstanding Voltage : AC 3700V/rms.(Between circuit and enclosure) 

Safety rules 

IEC61010-1(CAT Ⅲ 300V , CAT IV 150V , Pollution 2) ; IEC61010-031 ; 

IEC61557-1( Earth resistance ) ; IEC61557-5( Soil resistivity ) ; JJG 366-2004 . 


Tester: 1 pc;clamp: 2 pc;Auxiliary Earthing Rod: 4 pc;test line: 4 pc;simple testing line: 2 pc; RS232 line: 1 pc;disk: 1 pc;box:1pc 



Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview


Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
Trade Assurance
China (Mainland)
Transaction Level:
Supplier Assessments:
15 Transactions 120,000+
The supplier’s transactions conducted via Alibaba.com in the past 6 months.
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $61,000
Learn More